EchoSafe Explosion Proof Ultrasonic Transmitter
Unique Features
- Compact XP enclosure with viewing window and dual conduit ports
- Narrow 3" beam diameter enables flexible installations
- Applications with limited measurement space
- Sidewall installations
- Stand-pipe / Stilling Well installations
- Rugged corrosion resistant PVDF transducer and process mount
- Simple push button configuration enables quick setup/installation time
- Fail-safe intelligence with diagnostic feedback for easy troubleshooting
- Display indicated air gap or level height distance in inch or centimeter units
Description
FM approved explosion proof for use in hazardous applications, the two-wire ultrasonic transmitter provides non-contact level measurement up to 32.8' or 10 m, and is well suited for challenging corrosive, slurry or waste liquids. Push button calibrated, the transmitter is typically selected for atmospheric bulk storage, day tank and waste sump applications located within a classified area. Media examples include sodium hypochlorite, diesel fuel and paint. The integral display and push button module enable fast and simple calibration.
|
Range: |
XP88 8" tp 24.6' (20 cm to 7.5 m)XP89 8" to 32.8' (20 cm to 10 m) |
Process Temp: |
F: -4 to 140C:-20 to 60 |
|
Accuracy: |
+/- 0.2% of max. range |
Temp Comp: |
Automatic |
|
Resolution: |
0.079" (2mm) |
Electronics temp: |
F:-40 to 160C:-40 to 71 |
|
Beam width: |
3" (7.6 cm) dia. |
Pressure: |
30 psi (2 bar) |
|
Dead band: |
XP88: 8" (20 cm)XP99: 8" (20 cm) |
Enclosure rating: |
NEMA 4 |
|
Display type: |
LCD, 6-digits |
Enclosure mat: |
Aluminum |
|
Display units: |
Inch, cm or percent |
Window mat: |
Glass |
|
Memory: |
Non-volatile |
Transducer mat: |
PVDF |
|
Supply voltage: |
18-28 VDC (loop) |
Process mount: |
2" NPT |
|
Loop resistance: |
400 max @ 24 VDC |
Conduit entrance: |
Dual, 1/2" NPT |
|
Signal output: |
4-20 mA, two-wire |
Mount gasket: |
Viton |
|
Signal invert: |
4-20 mA or 20-4 mA |
Compliance: |
RoHS |
|
Calibration: |
Push button (3- button) |
Classification: |
Explosion proof |
|
Fail-safe: |
4 mA, 20 mA, 21 mA, 22 mA or hold last |
Approvals: |
FM: Class 1, Div 1Groups A,B,C,DClass II/III, Div 1Groups E,F,G |
Typical Applications
- FM approved explosion proof for use in hazardous applications
- Media examples include sodium hypochlorite, diesel fuel and paint.
Accessories
LM50 Side Mount Bracket - Wall Mount
Mount any 2" NPT transducer - Allows 3" clearance from wall - Perfect for Flow Line Options' 3 inch beam angle. LM50-5001-01 bracket for EchoPod 1" NPT